mitsubishi Euro 14SF Repair Tips
Search: Euro 14SF mitsubishi
Results 8
Results 8
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Mitsubishi | Euro 14SF CT25A5STX | hor lines across screen | C955 dry joints | ||
Mitsubishi | Euro 14SF CT25A5STX | Field collapse | Z551 cct prot o/c, IC5E1 TEA2031A on E/W pcb s/c but replacement failed shortly after replacement. L555 shorted turns (Pt no SEME TPAR2343) | ||
Mitsubishi | Euro 14SF | no / int sigs | dry joints on lead by PLL IC | ||
Mitsubishi | Euro 14SF | Field collapse (pic blanked) | Z551 315mA fuse in LOPTx 27v derived supply o/c, IC5E1 TEA2031A EW corr chip faulty - replaced but overheats. Possible causes - L554/5 | ||
Mitsubishi | Euro 14SF | dead or int dead | C914 47µ 35v is sus also C905 470µ 25v | ||
Mitsubishi | CT25A5STX Euro 14SF | Field collapse with E-W fault when FOP chip replaced | Replace TEA2031A FOP chip & L555 - which caused chips demise | ||
Mitsubishi | CT25A5STX Euro 14SF | Field collapse & Z551 cct prot o/c | IC5E1 TEA2031A on E/W module s/c due to L555 E/W loading coil s/c turns SEME pt no TPAR2343 | ||
Mitsubishi | CT25A5STX Euro 14SF | Field collapse | Z551 SOC3150 o/c, D553 BYD33G s/c, IC5E1 TEA2031 EW corr chip s/c pins 5 & 6, L555 15µH shorted turns |